IPAQ C530 is a modern, universal, HART® temperature transmitter developed to meet the highest standards of accuracy and reliability. It is compatible with both RTD and TC.
IPAQ C530 supports communication via NFC® and Bluetooth® which makes it possible to configure and monitor the transmitter remotely.
The robust design of the IPAQ 530 makes it highly reliable even under the most demanding conditions. External influences such as ambient temperature, vibrations up to 10 g, moisture and EMC interference have minimal influence on the measuring result.
IPAQ 530 helps you to get full control of the process. In addition to enhanced diagnostics via HART® 7, the transmitter can also measure the ambient temperature and supply voltage it has been exposed to. This allows you to detect peaks that could damage the process control.
Configure your IPAQ 530 wirelessly via NFC® (Near-field communication) by using the new app INOR Connect. With the new ICON-BT you can configure and monitor your IPAQ 530 also via Bluetooth. Thanks to the extended range that Bluetooth offers you can connect with the transmitter without removing it from the process. This series transmitters is also available for DIN-rail mounting, IPAQ R530.
Type | Head-mounted |
Input | RTD, TC, mV, ohm |
Input RTD | Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10 |
Input thermocouple | Type B, C, D, E, J, K, N, R, S, T |
Type of transmitter | Digital |
Output | 4-20 mA, HART protocol |
Galvanic isolation | 1500 VAC |
Measuring channels | 1 channel |
Sensor connection | 2-, 3-, 4-wire connection |
Power supply | IPAQ-C530: 8,5 to 36 VDC IPAQ-C530X: 8,5 to 30 VDC |
Approvals | ATEX, IECEx |
HART® compliance | Fully compliant with the HART® 7 protocol as well as the previous HART® 6 and 5. |
Typical accuracy | Max. ±0.08K or ±0.08% of span |
Accuracy over time | Max. drift ±0,02% of span/year |
Configuration | ConSoft, INOR Connect or EDD, DTM / FDT-system |
Wireless connectivity | NFC® and Bluetooth® * |
Vibration | IEC 60068-2-6, 10 g |
EMC | EN 61326-1 and EN 61326-2-3 |
Humidity | 0…98% RH (non-condensing) |
Ambient temperature | –40…+85 °C / -40…+185 °F |
Runtime counter | Hour counter for elapsed operational time |
Simulated output | Fixed current ouput during a maximum time of 15 min |
Adjustable filtering level | 0,17 to 90 s (standard 0.9 s) (3-wire RTD) |
Adjustments – Min. span | 10°C / 18°F or according to the sensor |
Adjustments – Zero point | Any value within range limits |
Sensor error | NAMUR NE43 |
Error compensation | Sensor and system error correction |
* Bluetooth® communication is only supported together with ICON-BT
Langkamp Technology B.V.
22 Molenvliet
3961 MV Wijk bij Duurstede
Netherlands
Phone: +31 (0)343-595410
info@ltbv.nl